Compact liquid-air cooling system with tank and pump
FLK series - in the power range from 1.1 to 10.5 kW
When cooling the process medium in the temperature range above 25 °C, the air convection cooling of the FLK cooler is an energy-saving alternative to compression cooling.
The circulating pump conveys the circulating medium over the component to be cooled back to the
DELTATHERM® liquid-air cooler. The series is ready for connection and has been tested for function and leaks.
For frost-free indoor installation.
Main applications of the FLK systems are:
Liquid-cooled motor spindles
Liquid-cooled drives
Liquid-cooled torque motors
Liquid-cooled servomotors
Liquid-cooled linear motors
Liquid-cooled converters
Liquid-cooled bearings
Liquid-cooled tools
Liquid-cooled welding systems
Liquid-cooled X-ray systems
Liquid-cooled CT or MRI systems
Short specification of the standard equipment
- Containermounted heat exchanger and submerged pump
- Motors and electrical switches prepared for direct connection by the customer
- Highly-efficient water / air heat exchanger made of copper tubing with pressed-on lamellae made of aluminium and a frame made of galvanised sheet steel
- Fan in axial design with suction-mounted sickle blade
- Direct drive via AC or three-phase current external rotor motor
- Maintenance-free and friction-optimised ball bearings
- Medium circuit
- Unit completely piped or hosed internally
- Externally mounted media connections
- Large-volume water tank made of HDPE / stainless steel / steel
- Free tank filling through a resealable filler
- Tank emptying option
- External contact protection in accordance with DIN 31001
- Protection class IP 54
Available options
- Complete control and regulation
- Level switch
- Air filter mat for air inlet at the heat exchanger
- Air filter mat monitoring
- Variable speed control of the fans
- Pump overflow valve for pump protection
- Manometer for display of the water outlet pressure
- Wire marking
- Heavy-duty connector (e.g. Harting)
- Flow monitor with analog or digital signal
- Water filter
- Gate valves in flow and return
- Check valves and solenoid valves for the water circuit (consumer higher than coolant)
- Tank filling via floater valve
- Automatic water backfeed with floater switch
- Tank heating for temperature control
- Pump switch-off
- Multi-circuit system
- 24V AC/DC control voltage
- Potential-free collective fault indicator
- External ON/OFF switching
- Special voltages and frequencies (50/60Hz)
- Limit temperature monitoring
- Differential temperature control
- External temperature sensor